XSPEC> thl 6.4,.34,7.1,20.,,,.015 ! Calculate the expected equivalent
width for a line at 6.4 keV with a
fluorescent yield of 34%. The
absorption edge is integrated from
7.1 keV to 20. keV in 200 steps. The
maximum depth is .015.
XSPEC> thleqw ,,,,,,100 ! As before, but with 100 steps
XSPEC> thleqw ! As before.
Don't forget to read the response file in again if you want to do further work
on the same data.