SUMMARY FILE FOR PROJECT: N20L2 COVER INFORMATION: Experiment: Network Monitoring Experiment Exp. Code: N20L2 Start Day 161 is Tue 9 Jun 2020 MJD 59009 Schedule Version: 3.00 Processed by SCHED version: 11.50 Development version 11.5. Started Apr. 2 PI: Olga Bayandina Address: JIVE Postbus 2 7990 AA Dwingeloo The Netherlands Phone: +31-521-596507 EMAIL: bayandina@jive.eu Fax: Phone during observation: +31-521-596507 Observing mode: Notes: 18cm NME and ftp fringe test for Session 2 2020 (512 Mbps, L+R, 2-bit sampling, 16 MHz filters) v3: includes Pi COVER LETTER: This is the schedule for the 18cm NME and ftp fringe-test on 9th June 2020 involving antennas: Jb2, Wb, Ef, On85, Ur, Hh, Sv, Zc, Bd, Ir, Ar. The NME uses a standard setup with 512 Mbps. The schedule consists of long integrations on calibrators J0121+1149, J0956+2515, and J0927+3902. The following ftp-fringe tests are scheduled throughout the experiment (UT times): 12:15:00 (scan 2, 2 sec, J0121+1149) + Arecibo 12:45:00 (scan 4, 2 sec, J0121+1149) + Arecibo 13:15:00 (scan 6, 2 sec, J0121+1149) + Arecibo 13:45:00 (scan 8, 2 sec, J0956+2515) 14:15:00 (scan 10, 2 sec, J0956+2515) 14:45:00 (scan 12, 2 sec, J0927+3902) Good luck with the session! Olga Bayandina Mattermost: coms.evlbi.org CORRELATION REQUESTS (Defaults in parentheses): Correlator (Required if recording): JIVE Correlator average time (2 sec): 1.000 sec. Alternate average time (for spacecraft). 0.000 sec. Output spectral channels per baseband (16): 16 Correlator FFT size (128): 128 Number of antennas to be correlated: 15 Polarization (ON): ON Correlator weighting function (UNIFORM): UNIFORM Distribution tape (DAT): FTP Distribution format (FITS): FITS Source positions from: STANDARD Shipping address for correlator output: Olga Bayandina Correlator Notes: May be with you DERIVED INFORMATION FOR CORRELATION: All scans Elapsed time for project (hours): 3.00 Total time in scheduled scans (hours): 2.32 Total time in recording scans (hours): 2.32 Total baseline hours (recording scans): 115.50 Projected max correlator output rate (kB/s): 270.3 Projected correlator output data size (MB): 1703.1 NOTES: Above numbers assume the same correlator parameters are used for all data. The 'baseline hours' include the autocorrelations (for data size calculations). The correlator output data rate is for real-time processing. Above numbers assume the same correlator parameters are used for all data. The recordings for a scan are assumed to start at the scan START minus PRESTART. Some stations (VLA, VLBA/MARK5C) wait for good data so the estimates may be high. STATIONS USED IN SCHEDULE: Station Code Latitude Longitude Elevation X Y Z Axis Offset JODRELL2 Jb 53.23396 2.30390 144. 3822846.760 -153802.280 5086285.900 0.458 WSTRBORK Wb 52.91529 -6.59391 71. 3828750.697 442589.218 5064921.570 4.950 EFLSBERG Ef 50.52483 -6.88361 417. 4033947.235 486990.794 4900431.002 0.014 ONSALA85 O8 57.39307 -11.91777 58. 3370965.879 711466.198 5349664.201 2.150 URUMQI Ur 43.47151 -87.17814 2033. 228310.181 4631922.902 4367064.211 0.000 HART Hh -25.88975 -27.68540 1416. 5085442.761 2668263.809 -2768696.729 6.694 SVETLOE Sv 60.53235 -29.78194 86. 2730173.647 1562442.798 5529969.156 -0.008 ZELENCHK Zc 43.78781 -41.56517 1175. 3451207.507 3060375.422 4391915.056 -0.011 BADARY Bd 51.77026 -102.23392 822. -838201.103 3865751.555 4987670.892 -0.005 IRBENE Ir 57.55338 -21.85481 59. 3183649.314 1276902.989 5359264.710 0.000 PICKMERE Pi 53.28872 2.44537 100. 3817549.956 -163031.141 5089896.654 0.000 ARECIBO Ar 18.34417 66.75270 451. 2390486.900 -5564731.440 1994720.450 0.000 Plate tectonic motion adjustments for MJD 59009 Station Code Station motions (m/yr) Adjusted positions X Y Z MJD0 X Y Z JODRELL2 Jb -0.0117 0.0170 0.0093 50449 3822846.486 -153801.881 5086286.118 WSTRBORK Wb -0.0135 0.0170 0.0087 50449 3828750.380 442589.617 5064921.775 EFLSBERG Ef -0.0144 0.0167 0.0106 56658 4033947.143 486990.902 4900431.070 ONSALA85 O8 -0.0144 0.0145 0.0105 56658 3370965.786 711466.291 5349664.268 URUMQI Ur -0.0323 -0.0014 0.0049 56658 228309.973 4631922.893 4367064.243 HART Hh -0.0010 0.0192 0.0162 56658 5085442.754 2668263.933 -2768696.625 SVETLOE Sv -0.0185 0.0133 0.0083 56658 2730173.528 1562442.883 5529969.209 ZELENCHK Zc -0.0225 0.0140 0.0077 56658 3451207.362 3060375.512 4391915.106 BADARY Bd -0.0277 0.0007 -0.0025 56658 -838201.281 3865751.559 4987670.876 IRBENE Ir -0.0169 0.0153 0.0064 57707 3183649.254 1276903.044 5359264.733 PICKMERE Pi -0.0117 0.0170 0.0093 50449 3817549.682 -163030.742 5089896.872 ARECIBO Ar 0.0099 0.0045 0.0101 52275 2390487.083 -5564731.356 1994720.636 BASELINE LENGTHS (km) Jb Wb Ef O8 Ur Hh Sv Zc Bd Ir Pi Ar Jb 0 597 700 1011 6028 8442 2082 3309 6156 1591 11 6394 Wb 597 0 267 602 5568 8240 1636 2729 5788 1095 606 6898 Ef 700 267 0 832 5652 8042 1804 2687 5930 1248 711 6911 O8 1011 602 832 0 5120 8525 1080 2538 5272 596 1016 7184 Ur 6028 5568 5652 5120 0 8853 4127 3586 1452 4580 6033 10690 Hh 8442 8240 8042 8525 8853 0 8697 7355 9833 8463 8449 9886 Sv 2082 1636 1804 1080 4127 8697 0 2015 4282 562 2086 7963 Zc 3309 2729 2687 2538 3586 7355 2015 0 4405 2046 3318 9015 Bd 6156 5788 5930 5272 1452 9833 4282 4405 0 4797 6158 10408 Ir 1591 1095 1248 596 4580 8463 562 2046 4797 0 1596 7665 Pi 11 606 711 1016 6033 8449 2086 3318 6158 1596 0 6387 Ar 6394 6898 6911 7184 10690 9886 7963 9015 10408 7665 6387 0 RECORDING SYSTEM AND CALIBRATION INFORMATION: List of scan-dependent controls seen for recording timing. MINPAUSE: 10. PRESTART: 0. DISKS - Stations potentially recording on disks. Station Drive type DAR NBBC Tsys JODRELL2 MARK5C DBBC 16 CONT WSTRBORK MARK5C DBBC 16 GAP EFLSBERG MARK5C DBBC 16 CONT ONSALA85 MARK5C DBBC 16 CONT URUMQI MARK5B DBBC 16 GAP HART MARK5C DBBC 16 CONT SVETLOE MARK5B R1002 14 GAP ZELENCHK MARK5B R1002 14 GAP BADARY MARK5B R1002 14 GAP IRBENE MARK5C DBBC 16 GAP PICKMERE MARK5C NONE 16 GAP ARECIBO MARK5C RDBE2 16 CONT EXPERIMENT SUMMARY: Number of input scans: 13 Number of scans scheduled: 13 Number of stations: 12 Number of sources input: 3 Number of setup files used: 1 STATION SCAN SUMMARIES: Station Control Scans Scan Record Record Gbytes Hours Hours Scans JODRELL2 VEX 13 2.32 2.32 13 537. WSTRBORK VEX 13 2.32 2.32 13 537. EFLSBERG VEX 13 2.32 2.32 13 537. ONSALA85 VEX 13 2.32 2.32 13 537. URUMQI VEX 7 1.28 1.28 7 296. HART VEX 7 1.28 1.28 7 298. SVETLOE VEX 9 1.52 1.52 9 350. ZELENCHK VEX 7 1.28 1.28 7 296. BADARY VEX 7 1.28 1.28 7 296. IRBENE VEX 13 2.32 2.32 13 537. PICKMERE VEX 13 2.32 2.32 13 537. ARECIBO VEX 6 1.03 1.03 6 240. Notes on the station scan summaries: "Record Scans" are periods of recording with no gap. The Mark5A disk systems have a limit of 1024 such scans. There are often multiple projects on a disk pack. If using MARK5A, try to keep above about 6 GB per record scan by using MINPAUSE and PRESTART to prevent short gaps. However, also try to prevent record scans of more than an hour to minimize risk to data from playback problems. MARK5C will have one observe scan per record scan and there is no limit to the number. SETUP FILES: ======== Setup file: sess220.L512ar Matching groups in /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat: arlb5c RX=LBW, with lfbf=5, upper 300 MHz CS 15-May-06 Setup group: 1 Station: ARECIBO Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 32.000 Number of channels: 8 DBE type: RDBE_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 2400.00 Net SB= U U U U U U U U IF SB = L L L L L L L L Pol. = RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 2 3 4 5 6 7 8 BBC SB= L L L L L L L L IF = A C A C A C A C The following frequency sets based on these setups were used. Frequency Set: 8 Setup file default. Used with PCAL = off LO sum= 1626.50 1626.50 1642.50 1642.50 1658.50 1658.50 1674.50 1674.50 BBC fr= 773.50 773.50 757.50 757.50 741.50 741.50 725.50 725.50 Bandwd= 16.00 16.00 16.00 16.00 16.00 16.00 16.00 16.00 Matching frequency sets: 8 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8 barrel=roll_off The following setup groups are the same as group 2 below. 3:ZELENCHK 4:BADARY ======== Setup file: sess220.L512ar Matching groups in /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat: kvzr_l passed by Alexey Melnikov, Mar2014 Setup group: 2 Station: SVETLOE Total bit rate: 512 Format: MARK5B Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: Speedup factor: 1.00 Disk used to record data. 1st LO= 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 1260.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A B A B A B A B A B A B A B A B The following frequency sets based on these setups were used. Frequency Set: 5 Setup file default. Used with PCAL = off LO sum= 1634.50 1634.50 1634.50 1634.50 1650.50 1650.50 1650.50 1650.50 1666.50 1666.50 1666.50 1666.50 1682.50 1682.50 1682.50 1682.50 BBC fr= 374.50 374.50 374.50 374.50 390.50 390.50 390.50 390.50 406.50 406.50 406.50 406.50 422.50 422.50 422.50 422.50 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 5 11 12 Track assignments are: track1= 18, 26, 2, 10, 20, 28, 4, 12, 22, 30, 6, 14, 24, 32, 8, 16 barrel=roll_off ======== Setup file: sess220.L512ar Matching groups in /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat: ef18cm 18cm Prime focus receiver, standard LO ****** Only 64.00 of 128.00 MHz total bandwidth is within the IFs in the setup file before any FREQ or DOPPLER shifts. Setup group: 5 Station: EFLSBERG Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A2 C4 A2 C4 A2 C4 A2 C4 A2 C4 A2 C4 A2 C4 A2 C4 The following frequency sets based on these setups were used. Frequency Set: 3 Setup file default. Used with PCAL = off LO sum= 1634.50 1634.50 1634.50 1634.50 1650.50 1650.50 1650.50 1650.50 1666.50 1666.50 1666.50 1666.50 1682.50 1682.50 1682.50 1682.50 BBC fr= 124.50 124.50 124.50 124.50 140.50 140.50 140.50 140.50 156.50 156.50 156.50 156.50 172.50 172.50 172.50 172.50 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 3 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess220.L512ar --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 6 Station: WSTRBORK Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 1247.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 A1 B1 The following frequency sets based on these setups were used. Frequency Set: 2 Setup file default. Used with PCAL = off LO sum= 1634.50 1634.50 1634.50 1634.50 1650.50 1650.50 1650.50 1650.50 1666.50 1666.50 1666.50 1666.50 1682.50 1682.50 1682.50 1682.50 BBC fr= 387.50 387.50 387.50 387.50 403.50 403.50 403.50 403.50 419.50 419.50 419.50 419.50 435.50 435.50 435.50 435.50 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 2 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess220.L512ar --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 7 Station: JODRELL2 Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 2272.00 Net SB= L L U U L L U U L L U U L L U U IF SB = L L L L L L L L L L L L L L L L Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= U U L L U U L L U U L L U U L L IF = A2 B2 A2 B2 A2 B2 A2 B2 A2 B2 A2 B2 A2 B2 A2 B2 The following frequency sets based on these setups were used. Frequency Set: 1 Setup file default. Used with PCAL = off LO sum= 1634.50 1634.50 1634.50 1634.50 1650.50 1650.50 1650.50 1650.50 1666.50 1666.50 1666.50 1666.50 1682.50 1682.50 1682.50 1682.50 BBC fr= 637.50 637.50 637.50 637.50 621.50 621.50 621.50 621.50 605.50 605.50 605.50 605.50 589.50 589.50 589.50 589.50 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 1 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess220.L512ar --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 8 Station: ONSALA85 Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 1220.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 The following frequency sets based on these setups were used. Frequency Set: 4 Setup file default. Used with PCAL = off LO sum= 1634.50 1634.50 1634.50 1634.50 1650.50 1650.50 1650.50 1650.50 1666.50 1666.50 1666.50 1666.50 1682.50 1682.50 1682.50 1682.50 BBC fr= 414.50 414.50 414.50 414.50 430.50 430.50 430.50 430.50 446.50 446.50 446.50 446.50 462.50 462.50 462.50 462.50 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 4 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess220.L512ar Matching groups in /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat: hh18cm Values confirmed by E-mail Jonathan Quick 20140219 (CR) ****** Only 64.00 of 128.00 MHz total bandwidth is within the IFs in the setup file before any FREQ or DOPPLER shifts. Setup group: 9 Station: HART Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 1510.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 A1 C1 The following frequency sets based on these setups were used. Frequency Set: 10 Setup file default. Used with PCAL = off LO sum= 1634.50 1634.50 1634.50 1634.50 1650.50 1650.50 1650.50 1650.50 1666.50 1666.50 1666.50 1666.50 1682.50 1682.50 1682.50 1682.50 BBC fr= 124.50 124.50 124.50 124.50 140.50 140.50 140.50 140.50 156.50 156.50 156.50 156.50 172.50 172.50 172.50 172.50 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 10 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess220.L512ar --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 10 Station: IRBENE Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 1350.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 A2 C2 The following frequency sets based on these setups were used. Frequency Set: 6 Setup file default. Used with PCAL = off LO sum= 1634.50 1634.50 1634.50 1634.50 1650.50 1650.50 1650.50 1650.50 1666.50 1666.50 1666.50 1666.50 1682.50 1682.50 1682.50 1682.50 BBC fr= 284.50 284.50 284.50 284.50 300.50 300.50 300.50 300.50 316.50 316.50 316.50 316.50 332.50 332.50 332.50 332.50 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 6 Track assignments are: track1= 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 barrel=roll_off ======== Setup file: sess220.L512ar --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 11 Station: URUMQI Total bit rate: 512 Format: MARK5B Bits per sample: 2 Sample rate: 16.000 Number of channels: 16 DBE type: DBBC_DDC Speedup factor: 1.00 Disk used to record data. 1st LO= 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 1300.00 Net SB= L L U U L L U U L L U U L L U U IF SB = U U U U U U U U U U U U U U U U Pol. = RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP RCP LCP BBC = 1 9 1 9 2 10 2 10 3 11 3 11 4 12 4 12 BBC SB= L L U U L L U U L L U U L L U U IF = A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 A2 C1 The following frequency sets based on these setups were used. Frequency Set: 9 Setup file default. Used with PCAL = off LO sum= 1634.50 1634.50 1634.50 1634.50 1650.50 1650.50 1650.50 1650.50 1666.50 1666.50 1666.50 1666.50 1682.50 1682.50 1682.50 1682.50 BBC fr= 334.50 334.50 334.50 334.50 350.50 350.50 350.50 350.50 366.50 366.50 366.50 366.50 382.50 382.50 382.50 382.50 Bandwd= 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 8.00 Matching frequency sets: 9 Track assignments are: track1= 18, 26, 2, 10, 20, 28, 4, 12, 22, 30, 6, 14, 24, 32, 8, 16 barrel=roll_off ======== Setup file: sess220.L512ar --- WARNING --- This group does not match an entry in the frequency catalog. This might be ok because the catalog is not complete. But be very careful to be sure that the setup is correct. Setup group: 12 Station: PICKMERE Total bit rate: 512 Format: VDIF Bits per sample: 2 Sample rate:128.000 Number of channels: 2 DBE type: Speedup factor: 1.00 Disk used to record data. 1st LO= 2272.00 2272.00 Net SB= U U IF SB = L L Pol. = RCP LCP BBC = 1 9 BBC SB= L L IF = A1 B1 The following frequency sets based on these setups were used. Frequency Set: 7 Setup file default. Used with PCAL = off LO sum= 1626.50 1626.50 BBC fr= 645.50 645.50 Bandwd= 64.00 64.00 Matching frequency sets: 7 Track assignments are: track1= 1, 2 barrel=roll_off SCAN SUMMARY for experiment N20L2 Network Monitoring Experiment Flags: D=>Down, H=>Below Horizon, R=>Rises, S=>Sets, W=>Slew too long, t=>Tape Chg. Top item is: Start elevation. Bottom item is: Seconds antenna is on source before scan start. TYPE top: -=> normal scan, P=>Pointing or Ta; bottom: -=>recording, N=>not recording. Day 161 is Tue 9 Jun 2020 MJD 59009 SCAN DAY START UT SOURCE TYPE STATIONS t => tape change STOP UT Jb Wb Ef O8 Ur Hh Sv Zc Bd Ir Pi Ar 1 161 12:00:00 J0121+1149 - 30 25 25 21 ---D ---D 12 ---D ---D 16 30 79 161 12:04:00 ss220.L512ar - 0 0 0 0 ---D ---D 0 ---D ---D 0 0 0 2 161 12:07:00 J0121+1149 - 29 24 24 20 ---D ---D 11 ---D ---D 15 29 80 161 12:17:00 - - 174 169 161 174 ---D ---D 174S ---D ---D 177 174 170 3 161 12:20:00 J0121+1149 - 27 22 22 18 ---D ---D ---D ---D ---D 13 27 82 161 12:32:00 - - 175 169 161 174 ---D ---D ---D ---D ---D 177 175 169 4 161 12:35:00 J0121+1149 - 25 20 20 16 ---D ---D ---D ---D ---D 11 25 84 161 12:47:00 - - 175 169 161 174 ---D ---D ---D ---D ---D 177 175 168 5 161 12:50:00 J0121+1149 - 23 17 17 14 ---D ---D ---D ---D ---D 9 23 83 161 13:02:00 - - 175 169 161 174 ---D ---D ---D ---D ---D 177 175 168 6 161 13:05:00 J0121+1149 - 21 15 15 12 ---D ---D ---D ---D ---D 7 21 81 161 13:17:00 - - 175 169 161 174 ---D ---D ---D ---D ---D 177 175 170 7 161 13:25:00 J0956+2515 - 42 47 49 48 55 35 52 70 43 52 42 ---D 161 13:32:00 - - -23 44 52 38 0 0 3906 0 0 402 -22 ---D 8 161 13:35:00 J0956+2515 - 44 49 50 49 53 36 53 71 41 53 44 ---D 161 13:47:00 - - 174 169 160 174 178 159 173 172 174 177 174 ---D 9 161 13:50:00 J0956+2515 - 46 51 52 51 50 37 53 71 39 54 46 ---D 161 14:02:00 - - 174 169 160 174 178 159 173 172 174 177 174 ---D 10 161 14:05:00 J0956+2515 - 48 53 54 52 48 38 54 71 36 55 48 ---D 161 14:17:00 - - 174 169 160 174 178 159 173 171 174 177 174 ---D 11 161 14:20:00 J0927+3902 - 65 69 71 69 47 25 68 79 39 71 64 ---D 161 14:32:00 - - 119 121 91 114 154 125 137 101 137 170 113 ---D 12 161 14:35:00 J0927+3902 - 67 71 73 70 44 25 68 77 37 71 66 ---D 161 14:47:00 - - 173 169 158 174 178 159 172 173 174 177 173 ---D 13 161 14:50:00 J0927+3902 - 69 73 75 71 41 25 68 74 35 71 68 ---D 161 15:00:00 - - 173 169 158 174 178 159 172 173 174 177 173 ---D SCAN SUMMARY for experiment N20L2 Network Monitoring Experiment Flags: D=>Down, H=>Below Horizon, R=>Rises, S=>Sets, W=>Slew too long, t=>Tape Chg. Top item is: Start azimuth. Bottom item is: End azimuth. TYPE top: -=> normal scan, P=>Pointing or Ta; bottom: -=>recording, N=>not recording. Day 161 is Tue 9 Jun 2020 MJD 59009 SCAN DAY START UT SOURCE TYPE STATIONS t => tape change STOP UT Jb Wb Ef O8 Ur Hh Sv Zc Bd Ir Pi Ar 1 161 12:00:00 J0121+1149 - 248 256 258 259 ---D ---D 634 ---D ---D -92 248 125 161 12:04:00 ss220.L512ar - 249 257 258 260 ---D ---D 635 ---D ---D -92 249 128 2 161 12:07:00 J0121+1149 - 250 258 259 261 ---D ---D 635 ---D ---D -91 250 131 161 12:17:00 - - 252 260 261 263 ---D ---D 637D ---D ---D -89 252 143 3 161 12:20:00 J0121+1149 - 253 261 262 263 ---D ---D ---D ---D ---D -88 253 148 161 12:32:00 - - 255 263 264 266 ---D ---D ---D ---D ---D -86 255 170 4 161 12:35:00 J0121+1149 - 256 264 265 267 ---D ---D ---D ---D ---D -85 256 177 161 12:47:00 - - 259 266 267 269 ---D ---D ---D ---D ---D -82 258 202 5 161 12:50:00 J0121+1149 - 259 267 268 270 ---D ---D ---D ---D ---D -82 259 208 161 13:02:00 - - 262 269 270 272 ---D ---D ---D ---D ---D -79 262 225 6 161 13:05:00 J0121+1149 - 262 270 271 273 ---D ---D ---D ---D ---D -79 262 228 161 13:17:00 - - 265 272 273 276 ---D ---D ---D ---D ---D -76 265 238 7 161 13:25:00 J0956+2515 - 105 113 111 124 251 25 510 517 617 -224 105 ---D 161 13:32:00 - - 107 115 113 126 253 23 512 522 618 -221 106 ---D 8 161 13:35:00 J0956+2515 - 107 116 114 127 254 22 513 524 619 -220 107 ---D 161 13:47:00 - - 110 120 117 130 256 19 518 532 621 -216 110 ---D 9 161 13:50:00 J0956+2515 - 111 120 118 131 257 18 519 534 622 -215 111 ---D 161 14:02:00 - - 114 124 122 135 260 15 523 543 625 -210 114 ---D 10 161 14:05:00 J0956+2515 - 115 125 123 136 260 14 524 545 625 -209 115 ---D 161 14:17:00 - - 118 129 127 140 263 11 529 553 628 -205 118 ---D 11 161 14:20:00 J0927+3902 - 112 124 119 142 285 1 542 608 646 -196 111 ---D 161 14:32:00 - - 116 129 124 148 286 358 549 613 648 -189 115 ---D 12 161 14:35:00 J0927+3902 - 117 131 125 150 287 358 550 615 649 -187 116 ---D 161 14:47:00 - - 121 137 132 156 288 355 556 619 650 -180 121 ---D 13 161 14:50:00 J0927+3902 - 122 139 134 158 289 354 558 619 651 -178 122 ---D 161 15:00:00 - - 126 145 140 164 290 352 563 622 653 -172 126 ---D SCAN SUMMARY for experiment N20L2 Network Monitoring Experiment Top item is: Slew time in seconds from previous source. Bottom item is: Nothing requested with SUMITEM. TYPE top: -=> normal scan, P=>Pointing or Ta; bottom: -=>recording, N=>not recording. Day 161 is Tue 9 Jun 2020 MJD 59009 SCAN DAY START UT SOURCE TYPE STATIONS t => tape change STOP UT Jb Wb Ef O8 Ur Hh Sv Zc Bd Ir Pi Ar 1 161 12:00:00 J0121+1149 - 0 0 0 0 --- --- 0 --- --- 0 0 5 161 12:04:00 ss220.L512ar - --- --- --- --- 2 161 12:07:00 J0121+1149 - 6 11 19 6 --- --- 6 --- --- 3 6 10 161 12:17:00 - - --- --- --- --- 3 161 12:20:00 J0121+1149 - 5 11 19 6 --- --- --- --- --- 3 5 11 161 12:32:00 - - --- --- --- --- --- 4 161 12:35:00 J0121+1149 - 5 11 19 6 --- --- --- --- --- 3 5 12 161 12:47:00 - - --- --- --- --- --- 5 161 12:50:00 J0121+1149 - 5 11 19 6 --- --- --- --- --- 3 5 12 161 13:02:00 - - --- --- --- --- --- 6 161 13:05:00 J0121+1149 - 5 11 19 6 --- --- --- --- --- 3 5 10 161 13:17:00 - - --- --- --- --- --- 7 161 13:25:00 J0956+2515 - 503 436 428 442 0 0 174 0 0 78 502 --- 161 13:32:00 - - --- 8 161 13:35:00 J0956+2515 - 6 11 20 6 2 21 7 8 6 3 6 --- 161 13:47:00 - - --- 9 161 13:50:00 J0956+2515 - 6 11 20 6 2 21 7 8 6 3 6 --- 161 14:02:00 - - --- 10 161 14:05:00 J0956+2515 - 6 11 20 6 2 21 7 9 6 3 6 --- 161 14:17:00 - - --- 11 161 14:20:00 J0927+3902 - 61 59 89 66 26 55 43 79 43 10 67 --- 161 14:32:00 - - --- 12 161 14:35:00 J0927+3902 - 7 11 22 6 2 21 8 7 6 3 7 --- 161 14:47:00 - - --- 13 161 14:50:00 J0927+3902 - 7 11 22 6 2 21 8 7 6 3 7 --- 161 15:00:00 - - --- TIME RANGE OF RECORDINGS and TOTAL BYTES: Obs. start time. Obs. end time. Total Station Day Time Day Time GBytes (UT) (UT) JODRELL2 161 12:00:00 161 15:00:00 537.2 WSTRBORK 161 12:00:00 161 15:00:00 537.2 EFLSBERG 161 12:00:00 161 15:00:00 537.2 ONSALA85 161 12:00:00 161 15:00:00 537.2 URUMQI 161 13:25:00 161 15:00:00 296.2 HART 161 13:25:00 161 15:00:00 297.6 SVETLOE 161 12:00:00 161 15:00:00 350.0 ZELENCHK 161 13:25:00 161 15:00:00 296.2 BADARY 161 13:25:00 161 15:00:00 296.2 IRBENE 161 12:00:00 161 15:00:00 537.2 PICKMERE 161 12:00:00 161 15:00:00 537.2 ARECIBO 161 12:00:00 161 13:17:00 239.6 POSITIONS OF SOURCES USED IN RECORDING SCANS Catalog positions marked with *. Precession of date coordinates is based on stop time of first scan. Names used in schedule marked with *. Observation date used in B1950/J2000 coordinate conversion (PRECDATE): 1979.900 No adjustments are made for rates (DRA, DDEC). Source Source position (RA/Dec) Error (B1950) (J2000) (Date) (mas) 0119+115 01 19 03.080126 * 01 21 41.595043 01 22 44.659337 0.00 * J0121+1149 11 34 09.31522 * 11 49 50.41321 11 56 02.19449 0.01 J0121+11 /home/guest/rmc/SCHED/sched11.5/catalogs/sources.gsfc GSFC 2016a X/S astro solution, 62476 observations. 4C39.25 09 23 55.319216 * 09 27 03.013937 09 28 17.387392 0.31 * J0927+3902 39 15 23.56644 * 39 02 20.85185 38 57 13.58826 0.16 0923+392 /home/guest/rmc/SCHED/sched11.5/catalogs/sources.gsfc J0927+39 GSFC 2016a X/S astro solution, 250526 observations. OK290 09 53 59.738482 * 09 56 49.875376 09 57 57.579236 0.41 * J0956+2515 25 29 33.58581 * 25 15 16.04991 25 09 35.99177 0.37 0953+254 /home/guest/rmc/SCHED/sched11.5/catalogs/sources.gsfc J0956+25 GSFC 2016a X/S astro solution, 26975 observations. SOURCE SCAN SUMMARY FOR SOURCES LISTED ABOVE Scan hours are for recording scans only. Baseline hours are only counted for scans above horizon at both ends. Source Setup file Frequency sets Observing hours (duplicates not shown) Scan Baseline J0121+1149 sess220.L512ar 1 2 3 4 5 6 7 8 1.033 22.167 J0927+3902 sess220.L512ar 1 2 3 4 5 6 7 9 10 0.567 31.167 J0956+2515 sess220.L512ar 1 2 3 4 5 6 7 9 10 0.717 39.298 EFFECT OF SOLAR CORONA The solar corona can cause unstable phases for sources too close to the Sun. SCHED provides warnings at individual scans for distances less than 10 degrees. The distance from the Sun to each source in this schedule is: Source Sun distance (deg) J0121+1149 55.7 J0927+3902 55.9 J0956+2515 64.3 Barry Clark estimates from predictions by Ketan Desai of IPM scattering sizes that the Sun will cause amplitude reductions on the longest VLBA baselines at a solar distance of 60deg F^(-0.6) where F is in GHz. For common VLBI bands, this is: 327 MHz 117. deg 610 MHz 81. deg 1.6 GHz 45. deg 2.3 GHz 36. deg 5.0 GHz 23. deg 8.4 GHz 17. deg 15.0 GHz 12. deg 22.0 GHz 9. deg 43.0 GHz 6. deg SOURCE SEPARATIONS Source separations in degrees for pairs closer than 30.00 degrees. J0927+3902 J0956+2515 15.1445 CATALOGS, FILES, and CODE VERSIONS Catalogs: Station: ../sta.sess220.115_RDBE.dat Version: 2018Sep07-20:14:11 Location: ../loc.sess220.115.dat Version: 2016Dec19-16:00:00 Frequency: /home/guest/rmc/SCHED/sched11.5/catalogs/freq_RDBE.dat Version: 2018Sep07-20:14:11 Source: /home/guest/rmc/SCHED/sched11.5/catalogs/sources.gsfc Version: Not given Source2: NONE Version: --- Other external files: Ephemeris: NONE PEAKFILE: /home/guest/rmc/SCHED/sched11.5/catalogs/peak.cmd MSGFILE: /home/guest/rmc/SCHED/sched11.5/catalogs/messages.txt Code versions: Release version: 11.50 Development version 11.5. Started Apr. 2 Version of VEX standard: 1.50 Version of VEX code: 0.87 Version of plot code: 1.06 Version of ephemeris code: 0.00 Version of PGPLOT: v5.3.1 This schedule produced on: Mon Jun 8 12:40:43 2020